Assessment of Respiratory Dynamics from ECG during Physical Exertion
Downloads
Published
DOI:
https://doi.org/10.58414/SCIENTIFICTEMPER.2026.17.1.06Keywords:
ECG Derived Respiration (EDR), Respiratory Dynamics, Physical Exertion, Central Moment Analysis, Wavelet Transform, Cardiorespiratory AssessmentDimensions Badge
Issue
Section
License
Copyright (c) 2026 The Scientific Temper

This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.
Background: Monitoring respiratory dynamics during physical exertion is crucial for assessing cardiopulmonary performance, particularly in fields like exercise physiology, sports science, and clinical rehabilitation. Traditional methods of monitoring respiration typically depend on specialized sensors, which can be inconvenient during active movement. ECG-Derived Respiration (EDR) provides a non-invasive option by obtaining respiratory data from electrocardiogram signals.Abstract
Purpose/Objective: This study intends to evaluate respiratory dynamics at the onset of physical activity through the use of EDR. Important respiratory metrics, including respiration rate, variations in signal amplitude, and rhythm, are evaluated from ECG recordings.
Methods: ECG signals were collected from healthy subjects during the first grade of treadmill exercise. A hybrid signal processing approach was applied, combining wavelet transform for decomposing the ECG into relevant frequency bands and central moment analysis for capturing respiratory-induced morphological variations. The derived respiratory signals were used to estimate key parameters and were validated against reference data from a thermistor based respiratory sensor.
Results: The derived respiratory signals exhibit a steady increase in respiratory rate and noticeable ECG waveform modulation while active. The central moment method is superior to the wavelet approach at capturing fine-grained respiratory signal changes, especially during low-intensity stress. We have shown that the proposed method works well, based on the strong correlation of predicted parameters with reference measurements.
Conclusion: This study presents evidence for the application of ECG-derived respiration for non-invasive monitoring of respiration during strenuous activity. The central moment method performed the best in the evaluation process and is likely the best method for real-time processing situations where accuracy and clarity of the signal will benefit from the additional frequency of the signal. This technique will be applicable to wearable health monitoring devices, sports and exercise physiology settings, early detection of cardiopulmonary stress, and all requiring minimal sensor hardware.
How to Cite
Downloads
Similar Articles
- Mohiyuddeen Hafzal, Gayathri B.J., M. Meghana Shet, Shaping the future: Education and skill development for Viksit Bharat@2047 , The Scientific Temper: Vol. 15 No. spl-2 (2024): The Scientific Temper
- Nisha Khan, Dr. Shriya Goyal, Politics of marriage: Exploring the intersection of love, violence and power in When I Hit You by Meena Kandasamy , The Scientific Temper: Vol. 16 No. 06 (2025): The Scientific Temper
- Dhruvina A Dabgar, Zankhana Pandit, Molecular Foundations of Life: An Integrated Study of Cell Biology and Genetics , The Scientific Temper: Vol. 16 No. 10 (2025): The Scientific Temper
- M. Monika, J. Merline Vinotha, A Sustainable Vendor–Buyer Supply Chain Framework Integrating Energy Storage Systems and Green Investments with Incentive Policies under Demand Uncertainty , The Scientific Temper: Vol. 17 No. 02 (2026): The Scientific Temper
- ABHAYA K. SINGH, IMPLICATIONS OF CLIMATE CHANGE IN THE HIMALAYAN REGION AND ITS IMPACT ON INDIAN SECURITY , The Scientific Temper: Vol. 2 No. 1&2 (2011): The Scientific Temper
- Ramya Singh, Archana Sharma, Nimit Gupta, Nursing on the edge: An empirical exploration of gig workers in healthcare and the unseen impacts on the nursing profession , The Scientific Temper: Vol. 15 No. 01 (2024): The Scientific Temper
- M. Iniyan, A. Banumathi, The WBANs: Steps towards a comprehensive analysis of wireless body area networks , The Scientific Temper: Vol. 15 No. 03 (2024): The Scientific Temper
- A. Anand, A. Nisha Jebaseeli, A comparative analysis of virtual machines and containers using queuing models , The Scientific Temper: Vol. 15 No. spl-1 (2024): The Scientific Temper
- Elizabeth Mize, A critical analysis of the continuing professional development of teachers in India through the lens of NEP 2020 , The Scientific Temper: Vol. 16 No. 03 (2025): The Scientific Temper
- Rekha Raghavendra, Shobha Gowda, Jissy Thomas, Fingerprint doorlock system using Arduino uno , The Scientific Temper: Vol. 16 No. Spl-2 (2025): The Scientific Temper
<< < 39 40 41 42 43 44 45 46 47 48 > >>
You may also start an advanced similarity search for this article.