Assessment of Respiratory Dynamics from ECG during Physical Exertion
Downloads
Published
DOI:
https://doi.org/10.58414/SCIENTIFICTEMPER.2026.17.1.06Keywords:
ECG Derived Respiration (EDR), Respiratory Dynamics, Physical Exertion, Central Moment Analysis, Wavelet Transform, Cardiorespiratory AssessmentDimensions Badge
Issue
Section
License
Copyright (c) 2026 The Scientific Temper

This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.
Background: Monitoring respiratory dynamics during physical exertion is crucial for assessing cardiopulmonary performance, particularly in fields like exercise physiology, sports science, and clinical rehabilitation. Traditional methods of monitoring respiration typically depend on specialized sensors, which can be inconvenient during active movement. ECG-Derived Respiration (EDR) provides a non-invasive option by obtaining respiratory data from electrocardiogram signals.Abstract
Purpose/Objective: This study intends to evaluate respiratory dynamics at the onset of physical activity through the use of EDR. Important respiratory metrics, including respiration rate, variations in signal amplitude, and rhythm, are evaluated from ECG recordings.
Methods: ECG signals were collected from healthy subjects during the first grade of treadmill exercise. A hybrid signal processing approach was applied, combining wavelet transform for decomposing the ECG into relevant frequency bands and central moment analysis for capturing respiratory-induced morphological variations. The derived respiratory signals were used to estimate key parameters and were validated against reference data from a thermistor based respiratory sensor.
Results: The derived respiratory signals exhibit a steady increase in respiratory rate and noticeable ECG waveform modulation while active. The central moment method is superior to the wavelet approach at capturing fine-grained respiratory signal changes, especially during low-intensity stress. We have shown that the proposed method works well, based on the strong correlation of predicted parameters with reference measurements.
Conclusion: This study presents evidence for the application of ECG-derived respiration for non-invasive monitoring of respiration during strenuous activity. The central moment method performed the best in the evaluation process and is likely the best method for real-time processing situations where accuracy and clarity of the signal will benefit from the additional frequency of the signal. This technique will be applicable to wearable health monitoring devices, sports and exercise physiology settings, early detection of cardiopulmonary stress, and all requiring minimal sensor hardware.
How to Cite
Downloads
Similar Articles
- Nivethra Selvaraj , Dr. R. Prathiba Devi, Eco-friendly natural dyes and their application on printing graphics , The Scientific Temper: Vol. 14 No. 02 (2023): The Scientific Temper
- Jasleen Kaur, Sultan Singh, Assessing the Impact of Stress on the Health and Job Performance of Employees in Indian Banks , The Scientific Temper: Vol. 14 No. 04 (2023): The Scientific Temper
- Priya Tiwari, Bharat Kasar, Vibhu Tripathi, Decoding Investor’s behavior in tax saving mutual fund: A multi-item scale for evaluating investors’ category , The Scientific Temper: Vol. 15 No. 04 (2024): The Scientific Temper
- Bhavesh Parekh, Parthiv Patel, Unravelling Indianness in R.K. Narayan’s novels: A multidisciplinary exploration of culture, tradition and modernity , The Scientific Temper: Vol. 16 No. 03 (2025): The Scientific Temper
- D. Selvaraj, A study on sustainable technology development of fintech 5.0 in Indian industries , The Scientific Temper: Vol. 16 No. Spl-2 (2025): The Scientific Temper
- Pijush Kanti Sinha, Dr. Anitha Arvind, Prof Monica Chaudhry, Impact of In-Office Dry Eye Therapy on Symptom Relief and Tear Film in Patients with Evaporative Dry Eye Disease in a Primary Optometry Clinic , The Scientific Temper: Vol. 17 No. 03 (2026): The Scientific Temper
- U.S.P. Sinha, R. Chakravorty, STUDIES ON THE PHOSPHATIC AND POTASSIC FERTILIZERS REQUIREMENT OF MULBERRY (Morus alba L.) BASED ON SOIL TEST VALUES , The Scientific Temper: Vol. 1 No. 01 (2010): The Scientific Temper
- Suresh Kumar, AGRO-WASTE MANAGEMNT BY VERMICOMPOSTING USING EISENIA FETIDA AND PERIONYX SANSIBARICUS EARTHWORMS , The Scientific Temper: Vol. 9 No. 1&2 (2018): The Scientific Temper
- Ahmed Mustefa, Ethiopian Voluntary Resettlement Programme-Lesson to Learn , The Scientific Temper: Vol. 14 No. 01 (2023): The Scientific Temper
- V.Samuthira Pandi, B. R. Senthil kumar, M Anusuya, Annu Dagar, Synthesis and characterization of ZnO, ZnO doped Ag2O nanoparticles and its photocatalytic activity , The Scientific Temper: Vol. 14 No. 03 (2023): The Scientific Temper
<< < 26 27 28 29 30 31 32 33 34 35 > >>
You may also start an advanced similarity search for this article.

