Short-term changes in lens vault post implantable collamer lens surgery in myopic patients
Downloads
Published
DOI:
https://doi.org/10.58414/SCIENTIFICTEMPER.2025.16.7.09Keywords:
Implantable Collamer Lens, Intraocular Pressure, Spherical Equivalent, Anterior Chamber Depth, Best Corrective Visual AcuityDimensions Badge
Issue
Section
License
Copyright (c) 2025 The Scientific Temper

This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.
Purpose: To evaluate short-term postoperative changes in lens vault and associated ocular parameters following Implantable Collamer Lens (ICL) implantation in myopic patients, and to identify preoperative predictors of vault behavior during the initial 15 days after surgery.Abstract
Subject and Methods: This cohort study included 202 eyes from 101 patients with myopia and astigmatism who underwent bilateral ICL implantation at Chaudhary Eye Centre & Laser Vision between October 2023 and December 2024. Preoperative and postoperative assessments included best-corrected visual acuity (BCVA), intraocular pressure (IOP), anterior chamber depth (ACD), and central vault measurements using the Anterion AS-OCT. Follow-ups were conducted on postoperative day 1 (POD 1) and day 15 (POD 15). Statistical analysis involved Wilcoxon tests, Fisher’s exact test, and mixed-model logistic regression to identify factors influencing vault changes.
Results: A significant reduction in lens vault was observed between POD 1 and 15 (mean difference = 50.5 μm; p < 0.001). ACD increased (mean = 0.0399 mm; p < 0.001), while IOP decreased (mean = 1.5 mmHg; p < 0.001). BCVA showed modest improvement (p = 0.041). Vault decreased in 75.2% of eyes, remained unchanged in 2%, and increased in 22.8%. Multivariate analysis revealed spherical equivalent (SE) as the only significant predictor of vault reduction (p < 0.001), with higher myopia associated with greater vault decrease.
Conclusion: Early postoperative changes in vault are significantly influenced by the degree of myopic correction. Higher preoperative myopia is associated with greater vault reduction, underscoring the importance of individualized preoperative planning and early postoperative monitoring to ensure optimal outcomes following ICL implantation.
How to Cite
Downloads
Similar Articles
- R. Gomathi, Balaji V, Sanjay R. Pawar, Ayesha Siddiqua, M. Dhanalakshmi, Ravi Rastogi, Ensuring ethical integrity and bias reduction in machine learning models , The Scientific Temper: Vol. 15 No. 01 (2024): The Scientific Temper
- Bhavya S, Prabha Lis Thomas, Effectiveness of Video Assisted Training Program on low back pain and functional disability among housekeeping employees in selected educational institutions in Bengaluru , The Scientific Temper: Vol. 16 No. 12 (2025): The Scientific Temper
- Shanmuganathi Ayyankalai, Srinivasaragavan Subburaj, Prasanna Kumari Nataraj, Measuring the research productivity on environmental toxicology: A scientometric study , The Scientific Temper: Vol. 16 No. 01 (2025): The Scientific Temper
- M.V. RADHAKRISHNAN, E. SUGUMARAN, EFFECT OF A BIODEGRADABLE SUBSTRATE SUGARCANE BAGASSE ON EGG AND SPERM QUALITY OF THE CATFISH, CLARIAS BATRACHUS (LINN.) , The Scientific Temper: Vol. 3 No. 1&2 (2012): The Scientific Temper
- Arunima Dey, New gender representation on the Indian OTT platform: A study on web series “Made in Heaven” , The Scientific Temper: Vol. 15 No. 01 (2024): The Scientific Temper
- Vibhu Tripathi, India’s stand on GM crops , The Scientific Temper: Vol. 16 No. 08 (2025): The Scientific Temper
- Josephine F S, W. Ritha, Economic Benefit of Construction Waste Management with Social Cost for Neighbourhood Communities , The Scientific Temper: Vol. 17 No. 05 (2026): The Scientific Temper
- G. Tripathi, R. Deora, FAUNA – ASSISTED LITTER DECOMPOSITION AND ITS IMPACT ON CHEMICAL AND BIOLOGICAL HEALTH OF BALANITES AEGYPTIACA BASED SILVIPASTURE SYSTEM , The Scientific Temper: Vol. 1 No. 01 (2010): The Scientific Temper
- Swetha Rajkumar, Subasree Palanisamy, Online detection and diagnosis of sensor faults for a non-linear system , The Scientific Temper: Vol. 14 No. 01 (2023): The Scientific Temper
- Brigith Gladys L, J. Merline Vinotha, Sustainable rough multi-objective two-stage solid transportation problem of third-party e-commerce logistic providers with conditional fixed parameter on safety , The Scientific Temper: Vol. 16 No. 01 (2025): The Scientific Temper
You may also start an advanced similarity search for this article.