Comparative accuracy of IOL power calculation formulas in nanophthalmic eyes undergoing cataract surgery
Downloads
Published
DOI:
https://doi.org/10.58414/SCIENTIFICTEMPER.2025.16.7.12Keywords:
Nanophthalmos, IOL power calculation, short axial length, cataract surgery, Accuracy of IOL PowerDimensions Badge
Issue
Section
License
Copyright (c) 2025 The Scientific Temper

This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.
Aim: To compare the predictive accuracy of three widely used IOL power calculation formulas—Hoffer Q, SRK/T, and SRK II—in adult patients with nanophthalmos undergoing cataract surgery or clear lens extraction. Methods: This retrospective observational study included 45 eyes with axial lengths ≤ 20.5 mm diagnosed with nanophthalmos. All patients underwent uncomplicated cataract surgery or clear lens extraction with posterior chamber IOL implantation. Preoperative biometry was performed using ZEISS IOL Master 700 or NANO AXIS A-scan. IOL power was calculated using Hoffer Q, SRK/T, and SRK II formulas. Postoperative spherical equivalent was recorded at one month, and prediction error was calculated as the difference between actual and predicted refraction. Mean absolute error (MAE) and percentage of eyes within ±0.25 D, ±0.50 D, ±1.00 D, and ±2.00 D were assessed. Statistical analysis included one-sample t-tests and descriptive statistics using SPSS version 26. Results: The Hoffer Q formula showed the lowest mean absolute prediction error (−0.44 ± 0.30 D), followed by SRK/T (+0.68 ± 0.73 D), while SRK II exhibited the highest error (+3.28 ± 0.52 D). The Hoffer Q formula demonstrated superior accuracy, with 75.6% of eyes within ±0.50 D and 93.3% within ±1.00 D of the target refraction. SRK II showed a statistically significant hyperopic shift (p < 0.001), whereas Hoffer Q and SRK/T did not show statistically significant differences from zero prediction error. Conclusion: Among the three formulas studied, the Hoffer Q formula provided the most accurate IOL power prediction in nanophthalmic eyes, with the lowest refractive error and highest consistency. These findings support the use of Hoffer Q in managing cataract patients with nanophthalmos and highlight the need for further evaluation of advanced formulas in this subgroup.Abstract
How to Cite
Downloads
Similar Articles
- Aman Bora, Ajay Kumar, Akhilesh Dwivedi, Exploring effective methods of conflict resolution: Strategies and challenges for sustainable peace , The Scientific Temper: Vol. 16 No. 06 (2025): The Scientific Temper
- Vimala S, G. Arockia Sahaya Sheela, Label-Aware Imputation with Cluster Refinement for Smartphone Usage Analytics in Educational Institutions , The Scientific Temper: Vol. 16 No. 12 (2025): The Scientific Temper
- Deepa H. Dwivedi, Rubee Lata, R. B. Ram, EFFECT OF BIO-FERTILIZER AND ORGANIC MANURES ON YIELD AND QUALITY OF GUAVA CV. RED FLESHED , The Scientific Temper: Vol. 1 No. 01 (2010): The Scientific Temper
- Richa Sharma, Shrutimita Mehta, Resilience in Resisting Spaces: Cross-Cultural Gender Identity in “Before We Visit the Goddess” , The Scientific Temper: Vol. 14 No. 04 (2023): The Scientific Temper
- S. Srinithiya, K. Menaka, Optimized Hybrid Feature Selection Techniques for Detecting Iron Deficiency Anemia , The Scientific Temper: Vol. 16 No. 12 (2025): The Scientific Temper
- S K Bairagi, Ram Chandra, R P Singh, Effect of Different Phosphorus and Potassium Levels on a Seed Crop of French Bean (Phaseolus vulgaris L.) , The Scientific Temper: Vol. 12 No. 1&2 (2021): The Scientific Temper
- Saba Naaz, K.B. Shiva Kumar, Integrated deep learning classification of Mudras of Bharatanatyam: A case of hand gesture recognition , The Scientific Temper: Vol. 14 No. 04 (2023): The Scientific Temper
- Vikas Jangra, Dr. Vikas Jangra, Vandana, Comparative study of color difference on coated and uncoated paper in digital printing , The Scientific Temper: Vol. 15 No. 01 (2024): The Scientific Temper
- K. Fathima, A. R. Mohamed Shanavas, TALEX: Transformer-Attention-Led EXplainable Feature Selection for Sentiment Classification , The Scientific Temper: Vol. 16 No. 11 (2025): The Scientific Temper
- Chhavi Kaushik, A.K. Chaubey, STUDIES ON THE EFFICACY OF NEEM AND FUNGAL ISOLATES ON MELOIDOGYNE INCOGNITA INFESTING SOLANUM MELONGENA L. , The Scientific Temper: Vol. 1 No. 01 (2010): The Scientific Temper
<< < 21 22 23 24 25 26 27 28 > >>
You may also start an advanced similarity search for this article.

